Power Line Carrier(PLC) Modem and Automatic Meter Reading (AMR) Intelligent Electric Cable Security Alarm System
กก
 
Intelligent  Electric Cable Security Alarm System
    The theft of electricity from the illumination supply line is always a difficult problem that the Public Light industry finds it virtually impossible to guard against. The Archnet Intelligent Electric Cable Security Alarm System is mainly used for the protection of low voltage power circuit and the communications cable against theft or tapping.
    It is an ideal product for securing the illumination and electrical supply line. This security alarm system makes use of Archnet's advanced spread spectrum power line carrier communication technology; and it can be integrated into the remote sensing, communication, and control system developed by the user. The system is an answer to all the power line security and monitoring needs of a city. The system diagram of the Intelligent Electric Cable Security Alarm System is shown as follows:
As can be seen in the diagram, the Intelligent Power Line (electric cable) Security Alarm System consists of a Alarm Terminal and a number of Power Line Monitoring units. The Alarm Terminal is installed inside the distribution panel of the distribution transformer. If the user has a remote monitoring system, this terminal can be directly connected to the remote system as an input. This input can be a Multi- switch or RS485/232 interface. If there is no direct connection to the user's remote monitoring system, the alarm message can be transmitted to the monitoring station or security personal via the public communication network, such as GSM, GPRS or SMS. The Circuit Monitoring Units are installed at the end of a cable section. 16 Circuit Monitoring Units can be installed at each distribution transformers. That means, the Alarm Terminal can monitor up to 16 cable sections. In case of any damage to the electric cable, the monitoring system can report the transformer number, section location of the damaged cable and time of the event to the management personnel at the Monitoring Station to take appropriate action.
Features:
1. Use of the existing electric cable to transmit the monitoring signal with no need of new data line, thus reducing installation cost. 
2. Reliable communication with or without electricity flowing in the cable.. 
3. Can be integrated into the existing remote control and management system, or as a standalone system using the public network including GSM, GPRS and SMS. 
4. Quick response time alarm warning signal depending on the number of circuit monitoring units connected to the alarm terminal. Alarm warning signals can be emitted within 10-30s. 
5. Accurate and detailed alarm report, including transformer serial number, circuit location, time of event, report time. 
6. Electromagnetic compatibility: the security alarm system conforms to IEC 1000-4-2, 3, 4, 5 EMC standards.